8. Analog to Digital conversion: Voltage and Resistance as integers in XO1 and XO1.5

The Measure Activity displays an oscillogram of the detected signal from the built-in microphone of the XO or an external one connected to the microphone input socket. Beyond this, its initial versions also displayed qualitative information onscreen relative to the readings from sensors connected to the netbook by means of a horizontal bar that was vertically displaced with changes in the signal. Starting with version 31, it was possible to read from the bottom part of the screen the integer value product of the AD conversion:

Sensors, DC (connect sensor to pink 'Mic In' on left side of XO)
Bias/Offset Disabled - Volts (-32768)

Current versions of this Activity return the integer value converted to Voltage or Resistance values that is being measured (example is an XO1.5 measuring on dual channel with version 36):

Voltage sensor (connect sensor to pink 'Mic In' on left side of XO)
Voltage - Volts (1.698) (1.693)

Resistive sensor (connect sensor to pink 'Mic In' on left side of XO)
Resistance - Ohms (420000000) (126730050)

By using the versions of Measure that we have referenced, we were able to obtain the A-D conversion to Voltage/integer and Resistance/integer that are shown below (going forward we will abbreviate integer into int when referring to an integer value).

Procedure

In order to achieve the goal set, you must make a decision with regard to the tester that we'll use as reference pattern with respect to which we'll contrast measurements taken by using the XO. This measuring instrument must meet the conditions to be of the highest quality possible, to be in optimum operating conditions and have been calibrated within the maximum time period set by the manufacturer. Before beginning to measure, the operator will have to verify that he is working within the parameters established by the manufacturer in order to consider the values obtained reliable.

In our case, we had two measuring instruments that were judged to be the most adequate:

  1. A digital multimeter (tester) of the FLUKE® brand, TRUE RMS MULTIMETER, model 87 (FLUKE 87)
  2. LabQuest Mini data acquisition interface and the corresponding sensors, of the Vernier brand (VERNIER LQM)

Both instruments belonging to the Physics Laboratory of Liceo Solymar N°1 (Ciudad de la Costa, Canelones). The latter was connected to a Magalhães Laptop model MG10T (distributed by Plan Ceibal to Secondary School students of Canelones). The software that was used to control the interface is called "Logger Pro for Linux Public Beta" which can be downloaded at no cost from the interface provider (VERNIER LPL).

The mentioned instruments were used within the conditions indicated by the manufacturer to take measurements. For example, for the multimeter they read: Operating Temperature: -20°C to 55°C and Relative Humidity between 0% and 90% (0 at 35°C). No correction of temperature coefficient was applied, because it was considered that other sources would be more significant in determining the precision and accuracy of measurements obtained with the XO.

NOTE: in the following graphs, the points are united by straight lines only in order to make a clear visualization of the tendency that the distribution follows. In any case this representation is wrong from a Physics point of view.

XO1: A-D conversion Voltage/integer

V(V) int
0,45 -30757
0,615 -23220
0,833 -13252
1,042 -3761
1,209 3874
1,42 13484
1,642 23561
1,809 31208
1,832 32249

AD conversion XO1 (V)

XO1: A-D conversion Resistance/integer

R(Ω) int
818 -30385
997 -26856
1180 -23534
1771 -14660
2190 -9577
4700 9286
6710 17256
8240 21457
10300 25547

AD conversion XO1 (R)

XO1.5: A-D conversion Voltage/integer

V(V) int
0,31 9291
0,603 7295
0,816 5840
1,029 4388
1,219 3105
1,402 1854
1,621 363
1,804 -883
1,959 -1947

AD conversion XO1.5 (V)

XO1.5: A-D conversion Resistance/integer

R(Ω) int
2190 25874
4700 22870
6710 20963
8240 19679
10300 18202
16090 15020
22000 12727
55700 6808
67500 5822
99600 4210

AD conversion XO1.5 (R)

Analysis of the A-D conversion curves obtained

Starting from the obtained results it can be observed that the Voltage/integer conversion follows a linear function (y=ax+b), therefore the procedure for calibrating will involve only determining values for a and b for the linear function and their validity ranges. On the contrary, the conversion Resistance/integer displays a non-linear link, implying a greater complexity since in order to obtain the resistance value that we're looking for, we must in the first place choose the best function that links the variables in order to determine the parameters that define it and find their range of validity. Based on this, we expect a lower precision in determining the resistance values measured by the XO, because of the larger amount of processing involved from the original integer to the final value obtained; we'll analyze this further ahead.